HYROX · Nivel 3: Preintermedio · Subnivel 3.5
Grip Strength and Endurance
10 tests · 100 datos · actualizado el 23 de noviembre de 2026 · markdown
Measuring grip, the grip endurance test, grip and leg fatigue, men's and women's grip, grip and health, grip cut-offs, grip and mortality, cautions about grip, grip agents, and chalk and friction.
Cada test de abajo son diez preguntas en Insporta. La lista bajo cada test es lo que comprueban las preguntas: un dato por pregunta, con su fuente. Léela antes del test o vuelve a ella tras una respuesta incorrecta.
Test 1Measuring gripHacer un test
Grip was measured with an electronic Jamar dynamometer.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
The second handle position was used.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Seated, shoulder at 0 degrees, elbow at 90 degrees, forearm neutral.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
The posture follows the American Society of Hand Therapists (1992).
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Only the dominant limb was tested: the hand people write with.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Visual feedback was given and verbal encouragement was standardised.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Warm-up was 3-5 grip repetitions on the Jamar.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Mean of reps 1-3: 33.6 kg; reps 10-12: 25.2 kg.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
A standard seated posture so results can be compared.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Warm up, squeeze twelve times, then compare the start with the end.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Test 2The grip endurance testHacer un test
12 maximal isometric contractions.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Each contraction was held for 3 seconds.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
5 seconds of rest between contractions.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
The mean of reps 1-3 was compared with the mean of reps 10-12.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
The grip fatigue index was 29.8%, about 30%.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
M2/M1 averaged about 75%.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Force rose slightly at rep 11, perhaps as effort dropped with fatigue.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Squeeze 3 s, rest 5 s, twelve times.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Twelve such cycles make the test.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Short holds, short rests, twelve repeats.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Test 3Grip and leg fatigueHacer un test
Quadriceps 18.1% against grip 29.8%.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Grip fatigued faster than the quadriceps (30% vs 18%).
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
The two fatigue indices correlated weakly and negatively.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Grip endurance should not be used as a surrogate for quadriceps endurance.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Possible reasons: fibre type, motor unit size and the high force demand.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
A 20% MVC protocol would favour slow-twitch fibres and might reverse the result.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Quadriceps were tested on a Biodex System II.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Grip about 30%, quadriceps about 18%.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Grip tired most.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Legs kept more of their starting force than hands.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Test 4Men's and women's gripHacer un test
21 healthy, recreationally active adults aged 18-35.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Men's M1 was 42.4 kg.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Women's M1 was 25.9 kg.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Men 28.1%, women 31.2%: not significantly different.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Quadriceps fatigue: men 22.8%, women 15.2% (significant).
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Normalisation changed little, except female grip endurance looked similar between M1 and M2.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Sex differences were too small to draw a definitive conclusion.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Men 42.4 kg, women 25.9 kg.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Both sexes lost about a quarter of their grip.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
A small convenience sample.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Test 5Grip and healthHacer un test
The review is titled 'Grip Strength: An Indispensable Biomarker For Older Adults'.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Grip relates to mortality, falls, fractures, cognition, depression and more.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
A single-author narrative review, not systematic.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Numerous different procedures, cut points and statistics were used.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Depression prevalence was 8.8% with weak grip against 3.8% without.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Byrnes et al. found grip not suitable for screening older inpatients for malnutrition.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Routine measurement can be recommended in community and health-care settings.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
8.8% with weak grip against 3.8% without.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Different studies set different lines for weak grip.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Cut-offs are lower for women and for the oldest group.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Test 6Grip cut-offsHacer un test
Cut-offs for heavy tasks: women 18.5 kg, men 28.5 kg.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Men 28.5 kg.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Sallinen: men 37.0 kg, women 21.0 kg.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Recent fallers 17.6 kg against 20.7 kg.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Slow walking was below 0.80 m/s.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Ozorio: men 19.3 kg, women 14.7 kg.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Cut points differ across studies.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Men 28.5 kg, women 18.5 kg.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Different outcomes, different cut-offs.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
The harder the task, the higher the cut-off.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Test 7Grip and mortalityHacer un test
Rijk et al.: pooled HR 1.79 for weak grip.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Wu et al.: HR 1.16 per 5 kg reduction.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Grip was a stronger predictor of cardiovascular death than systolic blood pressure.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Cancer mortality results were inconsistent (HR 0.97 and 1.10).
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Higher grip: HR 0.69.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Odds ratios of 1.08-1.21 for emergency admission or death.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Grip was related to hip fracture.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
A hazard ratio below 1 means lower risk.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Below 1 is protective; above 1 raises risk.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Even small grip losses carry measurable risk.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Test 8Cautions about gripHacer un test
Grip may not reflect overall strength; pair it with a lower-limb measure.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Use grip alongside a lower-limb measure.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Some associations are weak, around r = 0.25-0.36.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Poor validity as a single nutrition indicator.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Small sample; maximal values not confirmed; motivation not fully controlled.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Only young adults were tested; older adults and reference values are needed.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
A few participants reported mild grip discomfort.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Grip alone may not reflect overall strength.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Some links are tiny, others moderate.
Fuente: Bohannon 2019, Clinical Interventions in Aging 14:1681-1691
Better methods and wider groups.
Fuente: White et al. 2013, SpringerPlus 2:451 (CC BY)
Test 9Grip agentsHacer un test
Powdered chalk, liquid chalk, rosin and Venice turpentine.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
Only Venice turpentine significantly increased friction when dry.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
Rosin and powdered chalk decreased friction when dry: the particles acted as a lubricant.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
With a wet finger only the granular powder agents increased friction.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
With a wet surface water separated finger and steel; agents differed little.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
Under dry conditions a bare finger gave effective grip.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
The tests used one volunteer, a 22-year-old man.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
On porous sandstone moisture levels and agents made little difference.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
Match the agent to the moisture in the contact.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
Agents behaved differently as moisture rose.
Fuente: Carre et al. 2012, Proc IMechE Part J 226(J7):616-625
Test 10Chalk and frictionHacer un test
Sandstone, granite, dark limestone and light limestone.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
Static friction was measured at 5, 10 and 15 N.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
Chalk on dry fingertips improved static friction more than in sweaty conditions.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
Chalk made the static coefficient of friction more consistent.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
A generalisation cannot be made: the effect is situational.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
Larger grain sizes gave higher friction; ploughing is thought to dominate.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
Chalk is magnesium carbonate.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
5, 10 and 15 N were tested.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
Three loads, because climbers grip with varying force.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
Rocks, moisture, chalk, then friction compared.
Fuente: Clarke et al. 2024, Proc IMechE Part P (CC BY)
Fuentes
Official HYROX pages (The Fitness Race, The History, HYROX365), PUMA x HYROX guides, Concept2 technique pages, peer-reviewed HYROX research and open-access position stands; original questions authored, nothing reproduced. Numbered rules belong to the Rules category (HYROX - Rulebook).
- White et al. 2013, SpringerPlus 2:451 (CC BY)44
- Bohannon 2019, Clinical Interventions in Aging 14:1681-169136
- Carre et al. 2012, Proc IMechE Part J 226(J7):616-62510
- Clarke et al. 2024, Proc IMechE Part P (CC BY)10