HYROX · レベル6:上級 · サブレベル 6.2
Heart Rate Monitoring
テスト10件 · 事実98件 · 2026年11月23日 更新 · markdown
Why heart rate, resting heart-rate variability, exercise heart rate, heart-rate recovery, RMSSD, daily or weekly readings, reading changes, devices and routines, measuring well, and the limits of HRV.
以下の各テストは、Insporta の10問で構成されています。テストの下のリストは、問題が確認する内容です。1問につき1つの事実と、その元になった出典を載せています。テストの前に読むか、間違えたあとに戻ってきてください。
テスト 1Why heart rateテストを受ける
Resting, exercise and recovery heart rate are used for fatigue, fitness and performance.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Daily within training blocks and throughout the competitive season.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Contradictions in the literature, mostly from methods and interpretation.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Methodological inconsistencies and misreading data, not the measures themselves.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Blood lactate can track fitness; whether it shows fatigue is debated.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Each measure informs on a different aspect of autonomic activity.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Monitoring lets load be adjusted and individualised.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Resting, exercise and recovery heart rate are the three families.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Before, during and after the session.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Regular data, individual comparison, then a decision.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
テスト 2Resting heart-rate variabilityテストを受ける
HRV is the fluctuation in the intervals between consecutive heartbeats.
出典:Esco 2026, Sensors 26:3 (CC BY)
High HRV suggests parasympathetic predominance and recovery.
出典:Esco 2026, Sensors 26:3 (CC BY)
Low HRV reflects sympathetic activation or reduced vagal tone.
出典:Esco 2026, Sensors 26:3 (CC BY)
Some studies report HRV rising despite significant stress.
出典:Esco 2026, Sensors 26:3 (CC BY)
Vagal indices capture cardiac parasympathetic activity.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
5-min resting recordings capturing beat-to-beat changes.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Exercise HR and recovery changed within a week; resting HRV after week 4.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Resting HRV lagged the other two measures by about three weeks.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Each measure follows its own time course.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
High HRV suggests recovery; low HRV stress or fatigue.
出典:Esco 2026, Sensors 26:3 (CC BY)
テスト 3Exercise heart rateテストを受ける
Depending on intensity, at least 3-4 minutes.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
The average over the last 30-60 s is used.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
The lower the HR at a given intensity, the fitter the athlete.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
An increased HR should not be used as a clear fatigue marker.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
A >4% increase in HRex predicted next-day sickness.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
It has greater predictive ability within the first months.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Lower HR at the same submaximal pace means better fitness.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Fixed intensity, steady state, then a short average.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Lower submaximal heart rate goes with higher fitness.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
テスト 4Heart-rate recoveryテストを受ける
HRR tracks the fall in heart rate after exercise.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
HRR60s counts beats recovered within 60 s.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
HRR is generally accelerated in high-volume athletes.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
The greater the load, the slower the HRR.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Metaboreflex drives sympathetic withdrawal and parasympathetic reactivation.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
HRR did not always correlate with performance in team sports.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Post-exercise HRV may be similarly or less useful.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
HRR60s counts the beats recovered in 60 seconds.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Autonomic changes bring heart rate down.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Fitness speeds HRR; heavy recent load slows it.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
テスト 5RMSSDテストを受ける
The root mean square of successive R-R interval differences.
出典:Esco 2026, Sensors 26:3 (CC BY)
RMSSD reflects vagal activity.
出典:Esco 2026, Sensors 26:3 (CC BY)
SD1 and RMSSD are mathematically equivalent.
出典:Esco 2026, Sensors 26:3 (CC BY)
HRV values are right-skewed, so a natural log stabilises variance.
出典:Esco 2026, Sensors 26:3 (CC BY)
RMSSD and SD1 have very low sensitivity to breathing patterns.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
RMSSD CV about 12% against about 82% for LF/HF.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
He discourages spectral indices in the field.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
CV about 12% for RMSSD against 82% for LF/HF.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Root mean square of successive differences.
出典:Esco 2026, Sensors 26:3 (CC BY)
Time-domain metrics are preferred in mobile settings.
出典:Esco 2026, Sensors 26:3 (CC BY)
テスト 6Daily or weeklyテストを受ける
Isolated readings are susceptible to transient fluctuations.
出典:Esco 2026, Sensors 26:3 (CC BY)
Baseline needs frequent measurements over at least a week.
出典:Esco 2026, Sensors 26:3 (CC BY)
Plews: five for recreational, three for highly trained.
出典:Esco 2026, Sensors 26:3 (CC BY)
Three days sufficed for highly trained athletes.
出典:Esco 2026, Sensors 26:3 (CC BY)
Weekly averaged RMSSD tracks long-term adaptation.
出典:Esco 2026, Sensors 26:3 (CC BY)
The CV within a fixed week captures acute perturbations.
出典:Esco 2026, Sensors 26:3 (CC BY)
Greater perturbations in autonomic homeostasis.
出典:Esco 2026, Sensors 26:3 (CC BY)
Weekly averages smooth out day-to-day noise.
出典:Esco 2026, Sensors 26:3 (CC BY)
Daily recordings remain the gold standard.
出典:Esco 2026, Sensors 26:3 (CC BY)
Baseline, regular recordings, then weekly comparison.
出典:Esco 2026, Sensors 26:3 (CC BY)
テスト 7Reading changesテストを受ける
The change from week 1 to 3 correlated r = 0.90 with VO2max at week 12.
出典:Esco 2026, Sensors 26:3 (CC BY)
Weekly RMSSD CV correlated r ≈ 0.92 with race performance.
出典:Esco 2026, Sensors 26:3 (CC BY)
Resting HRV r = 0.76, slightly above HR at r = 0.73.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Only slightly below HRV (0.76).
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
r = 0.88 for HRV against 0.81 for HR.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Changes should be read relative to measurement error and the SWC.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Weekly shifts can signal that load or recovery needs adjusting.
出典:Esco 2026, Sensors 26:3 (CC BY)
0.76 against 0.73.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
All are large, but they differ in strength.
出典:Esco 2026, Sensors 26:3 (CC BY)
Rising variation and a falling mean suggest poor recovery.
出典:Esco 2026, Sensors 26:3 (CC BY)
テスト 8Devices and routinesテストを受ける
ECG detects each R-wave precisely.
出典:Esco 2026, Sensors 26:3 (CC BY)
23 studies comparing chest straps, wrist devices and phone apps with ECG.
出典:Esco 2026, Sensors 26:3 (CC BY)
RMSSD showed the lowest error regardless of device or posture.
出典:Esco 2026, Sensors 26:3 (CC BY)
Motion artefacts and vascular changes distort PPG during exercise.
出典:Esco 2026, Sensors 26:3 (CC BY)
PPG reflects the pulse, not the heart's electrical signal.
出典:Esco 2026, Sensors 26:3 (CC BY)
Record after waking and elimination, before food or stimulants.
出典:Esco 2026, Sensors 26:3 (CC BY)
A 1-min segment after a 1-min stabilisation agrees well.
出典:Esco 2026, Sensors 26:3 (CC BY)
1 minute for RMSSD against 3-5 minutes for frequency measures.
出典:Esco 2026, Sensors 26:3 (CC BY)
Bladder, digestion and caffeine all change vagal tone.
出典:Esco 2026, Sensors 26:3 (CC BY)
RMSSD tolerates the shortest recordings.
出典:Esco 2026, Sensors 26:3 (CC BY)
テスト 9Measuring wellテストを受ける
The supine condition is better tolerated in the field.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Night recordings are noisy and difficult to run daily.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
No significant differences and strong correlations.
出典:Esco 2026, Sensors 26:3 (CC BY)
Waking HRV was sensitive; later-day readings less so.
出典:Esco 2026, Sensors 26:3 (CC BY)
Morning RMSSD was more strongly associated with 2000 m rowing.
出典:Esco 2026, Sensors 26:3 (CC BY)
R-R series editing is often overlooked.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Above VT1, breathing increasingly drives HRV.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
Consistency of time, posture and duration matters.
出典:Esco 2026, Sensors 26:3 (CC BY)
Heavy weeks give large swings, so use a typical week.
出典:Esco 2026, Sensors 26:3 (CC BY)
テスト 10Limitsテストを受ける
RMSSD focuses solely on parasympathetic activity.
出典:Esco 2026, Sensors 26:3 (CC BY)
Alcohol, sleep, illness and other factors can sway it.
出典:Esco 2026, Sensors 26:3 (CC BY)
Integration with other markers and machine learning.
出典:Esco 2026, Sensors 26:3 (CC BY)
Session intensity is adjusted from the morning HRV value.
出典:Esco 2026, Sensors 26:3 (CC BY)
Scaling turns lnRMSSD 4.2 into a 'score' of 84.
出典:Esco 2026, Sensors 26:3 (CC BY)
Intensity must stay below each player's VT1, impractical in groups.
出典:Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)
RMSSD is susceptible to external confounders.
出典:Esco 2026, Sensors 26:3 (CC BY)
Chest straps yield highly accurate ECG-like signals; wrist PPG suffers in motion.
出典:Esco 2026, Sensors 26:3 (CC BY)
ECG is the gold standard; PPG loses accuracy in motion.
出典:Esco 2026, Sensors 26:3 (CC BY)
Rule out confounders before acting on a trend.
出典:Esco 2026, Sensors 26:3 (CC BY)
出典
Official HYROX pages (The Fitness Race, The History, HYROX365), PUMA x HYROX guides, Concept2 technique pages, peer-reviewed HYROX research and open-access position stands; original questions authored, nothing reproduced. Numbered rules belong to the Rules category (HYROX - Rulebook).
- Esco 2026, Sensors 26:3 (CC BY)50
- Buchheit 2014, Frontiers in Physiology 5:73 (CC BY)48